Snohomish County, Washington
Sultan is a city in Snohomish County, Washington. Sultan adopts its own zoning, so inside its limits Sultan’s rules apply, not the county’s. 12 rules below are quoted from official sources and independently re-checked, most recently on October 24, 2026. Rules for unincorporated land are on the Snohomish County page.
Buildings and structures inside Sultan city limits.
International Building Code edition: 2021 (With statewide amendments and local amendments stated in the ordinance.) · International Residential Code edition: 2021 (With statewide amendments.)
“The 2021 International Building Code, published by the International Code Council, Inc., with statewide amendments and as amended within this document;”
A proposed use for which Sultan requires a sewer general facility charge.
“If a sewer general facility charge is required, no building permit or certificate of occupancy shall be issued until the corresponding connection fee is paid.”
Land inside Sultan city limits.
“No building or land shall be used and no building shall be erected or altered except in conformity with the regulations herein prescribed for the district designated and identified on the zoning map in which such building or land is located.”
Zoning districts inside Sultan city limits.
zoning districts: 8 districts (Plus one overlay district.)
“The City of Sultan is hereby divided into eight zoning districts and one overlay district as follows:”
HUD-certified manufactured homes inside Sultan city limits, in zoning districts permitting single-family dwellings.
“Manufactured homes as defined in SMC § 16.04.130.2, and manufactured housing constructed prior to June 15, 1976, which has been HUD-certified and found by inspection of the city to be safe and fit for residential occupancy, are classified as single-family dwellings and permitted in all zoning districts in which single-family dwellings are permitted.”
Privies, septic tanks, drain fields, cesspools, and other sewage-disposal facilities inside Sultan city limits.
“Except as hereinafter provided, it shall be unlawful to construct, enlarge, replace, or modify any privy, privy vault, septic tank and/or drain field, cesspool, or other facility intended or used for the disposal of sewage except for new septic systems as allowed by Sultan General Sewer Plan Chapter 5, Septic Systems Policies, and Sultan zoning code regulations SMC § 16.20.045, New septic system reasonable use exception – Future sewer connection required, notwithstanding the routine maintenance of an existing, fully functional septic system.”
Properties inside Sultan corporate limits with public sewer available.
sewer-main availability distance: <= 300 feet (Measured from the downstream property boundary.)
“Within the corporate city limits where a public sewer is available, it must be used. Connection to the public sewer shall also occur when mandated by the Department of Health. Public sewer is considered available where the downstream boundary of the property is within 300 feet of that sewer main.”
Sewer connections and sewer general facility charges inside Sultan city limits.
“Sewer rates shall be set by separate ordinance and included as an attachment to the annual fee schedule adopted by the city council.”
Connection to Sultan's public sewer system.
“No person shall uncover, make connection with, alter or disturb any public sewer or appurtenance without first obtaining a permit from the public works department.”
Sultan does not set these itself; the county, a health district or the state does, and they apply to every address inside its limits.
Detached building forms in Sultan's Low Density Residential zone.
minimum lot area: >= 8600 square feet (Existing lots are exempt from minimum-area requirements.) · minimum lot width: >= 70 feet · minimum lot depth: >= 100 feet
“Detached building forms | 8,600 sq. ft. | 70 | 100 | 20 | 5 | 15 | 30 | 50”
Detached building forms in Sultan's Low Density Residential zone.
maximum lot coverage: <= 50 percent
“Uses Permitted | Minimum Lot Size Dimensions | Minimum Yard Setback(ft) | Max. Bldg. Height(ft) | Max. Lot Coverage(%)”
Detached building forms in Sultan's Low Density Residential zone.
maximum building height: <= 30 feet (Flood pedestals in flood-prone areas are not counted toward building height.)
“Flood pedestals are encouraged in flood-prone areas. Flood pedestals will not be counted towards building height and should be sized according to need based on FEMA flood maps.”
We looked and could not find an official answer yet. Silence is not permission; ask Sultan or Snohomish County directly.
Each answer was extracted from an official source and independently re-checked against that source by a second reviewer. That is an evidence check, not legal advice. Rules change; confirm with the authority before you buy or build.
Unanswered questions are usually a sign that Sultan publishes no rule on the point, not that none exists. Snohomish County’s page lists the county offices to call.
Off-grid gear
Going off-grid in Sultan means bringing your own water and power. The kit we’d start with:
These are affiliate links — we may earn a commission, at no cost to you. As an Amazon Associate, Bolthole Index earns from qualifying purchases.